Model Detail
Broan-NuTone LLC Broan B180E75RT
ERVs
 
Volts
Amps
EATR 50
EATR 100
 
  120   2.57 2.81
Airflow Ratings
 
Ext. Static Pressure (Pa)
Ext. Static Pressure (in. wg)
Net Supply Airflow (L/s)
Net Supply Airflow (cfm)
Gross Airflow Supply (L/s)
Gross Airflow Supply (cfm)
Gross Airflow Exhaust (L/s)
Gross Airflow Exhaust (cfm)
 
  25 0.1 90 191 93 197 93 197
  50 0.2 89 189 92 195 92 195
  75 0.3 88 186 91 193 91 193
  100 0.4 86 182 89 189 89 189
  125 0.5 84 178 87 184 87 184
  150 0.6 82 174 85 180 85 180
  175 0.7 81 172 84 178 84 178
  200 0.8 79 167 82 174 82 174
  225 0.9 78 165 81 172 81 172
  250 1.0 76 161 79 167 79 167
  275 1.1 73 155 76 161 76 161
  300 1.2 72 153 74 157 74 157
Energy Ratings
 
Brand Name
Model
Temp Mode
˘XC2
˘XF2
Net Airflow (L/s)
Net Airflow (cfm)
Power Consumed (Watts)
SRE
ASRE
Latent Recovery / Moisture Transfer
TRE
ATRE
VLTVRF Supply (%)
VLTVRF Exhaust (%)
Very Low Temp Airflow Imbalance (%)
 
  Broan B180E75RT HEATING 0 32 31.0 66 23 81.0 83 0.63          
  Broan B180E75RT HEATING 0 32 38.0 81 33 78.0 81 0.60          
  Broan B180E75RT HEATING 0 32 76.0 161 135 72.0 77 0.52          
  Broan B180E75RT HEATING -25 -13 39.0 83 79 64.0 67 0.64     30.0 30.0 101
  Broan B180E75RT COOLING 35 95 31.0 66 24     0.65 68 69      
  Broan B180E75RT COOLING 35 95 38.0 81 35     0.63 65 67      
  Broan B180E75RT COOLING 35 95 76.0 161 150     0.53 52 56      
Show fields from Show fields from Show fields from a related table
Report Name *
Description
Reports and Charts Panel
Each table has a panel listing its reports and charts, organized in groups.
Please wait while your new report is saved...
Field label
Column heading override
Justification
What does auto mean?
Fields in:

Fields to Extract:

Name for the new table:
Items in the new table are called:

When you bring additional fields into a conversion, Quickbase often finds inconsistencies. For example, say you're converting your Companies column into its own table. One company, Acme Corporation, has offices in New York, Dallas and Portland. So, when you add the City column to the conversion, Quickbase finds three different locations for Acme. A single value in the column you're converting can only match one value in any additional field. Quickbase needs you to clean up the extra cities before it can create your new table. To do so, you have one of two choices:

  • If you want to create three separate Acme records (Acme-New York, Acme-Dallas and Acme-Portland) click the Conform link at the top of the column.
  • If the dissimilar entries are mistakes (say Acme only has one office in New York and the other locations are data-entry errors) go back into your table and correct the inconsistencies—in this case, changing all locations to New York. Then try the conversion again.

Read more about converting a column into a table.

We're glad you're interested in doing more with Quickbase!

Now we need to make you official before you share apps or manage your account.

Verifying your email lets you share Quickbase with others in your company.

Your work email
Your company